TOTOKU CCL 354i2

3 MP display for diagnostic imaging

High Luminance Monitor TOTOKU CCL 354i2

A high-performance model not only offers high image quality and high-accuracy, but also is loaded with quality maintenance management features.

With very high luminance of up to 800 cd/m², and an integrated color calibration function, our CCL354i2 delivers highly accurate color reproduction faithful to the DICOM GSDF.

The CCL354i2 includes a luminance compensation feature for edge to edge consistency, is fully configurable for multi-display applications, and comes standard withhardware-based pivot functionality for fast image drawing in portrait orientation.

Product-Features

  • 21.3" Color Display
  • Brightness: 800 cd/m² (calibrated to 410cd/m² by factory default)
  • Contrast Ratio: 750:1
  • Medical Grade LCD-Monitor
  • Remote Calibration (PM Medivisor required)
  • Continuous DICOM Check (PM Medivisor required)
  • Uniformity Correction (Medivisor for i2 Series required)
  • Super fine Uniformity Correction preset
  • 5 Years Warranty incl. Backlight
  • Resolution: 2048 x 1536 or 1536 x 2048 / 3 Megapixel
  • Luminance Stabilization Sentinel-2

Remote Calibration Capability

TOTOKU Uniformity Correction

The i2-models are equipped with an improved front sensor. Its accuracy opens up the opportunity of true remote calibration. The matching "PM-Medivisor" software is also available from TOTOKU.

It offers additional features, such as a continuous and automatic check of DICOM conformity.  This check is performed in the background unnoticed by the user and the results are reported to the user or the network administrator. All measured values are displayed in a clearly arranged graphic diagram.

 

 

The Uniformity Correction

TOTOKU Uniformity Correction

The i2-models feature a Uniformity Correction developed by TOTOKU. It involves subdividing the screen surface into multiple zones and performing extensive measurements on these zones. A combination of electronics and software is then used to adjust the brightness of the individual zones, much like in an equalizer, such that even minimal differences are eliminated in the process. This results in homogeneous luminance across the entire surface of the screen. The process can be repeated by the user at any time using the appropriate calibration software and a sensor. 

The Lambda Sentinel II

Lambda-Sentinel II Technology

The new TOTOKU i-Models have λ-Sentinel-II, an advanced automatic luminance control system that adjusts the luminance in perfection. The luminance sensor is places in front of the panel surface and stabilizes luminance by a permanent monitoring and sending feedback to the control circuit.

 

Calibration function to accurately adjust gamma, color temperature, and luminance

The calibration function creates the optimum conditions for a medical imaging display by adjusting luminance levels, color temperature, and grayscale characteristics to achieve DICOM GSDF compliant grayscale output.

more about the calibration function

LED Indicator

A glance at the LED indicator tells you the display's current operating status in three distinct colors. When in normal mode (luminance is stabilized), the LED is not lighted to minimize negatively impacting the diagnostic interpretation.

more about the LED Indicator

Worldwide valid safety standards for the medical field

TOTOKU monitors are completely certified according to the medical safety standards, which have more strictly demands than the safeties requirements for standard displays.

more about medical safety standards

Hardware Pivot Function

The pivot function allows for a 90-degree rotation of the LCD panel into portrait orientation.

more about the Hardware Pivot Function

 